Chapter 9 Messages
9.1 Event Log Messages

ETERNUS VSS Hardware Provider 2.1 User’s Guide

Copyright 2012 FUJITSU LIMITED

P3AM-4582-03ENZ0

92

Event ID: 2005

Type:Error

Messages:STXV2005 ERROR The timeout value is invalid.

Details:

The timeout value is invalid. The process is canceled.
Change the timeout value that was specified in the registry, and try again.

Event ID: 2006

Type:Error

Messages:STXV2006 ERROR An error was detected during communication process.

Details:

An error was detected during communication process. The process is canceled.
Check the communication environment between the production server and backup server.
If there is no problem in the communication environment, refer to

"10.2 How to Obtain Error

Information" (page 131)

, and prepare the required information before contacting a Fujitsu field

engineer (FE).

Event ID: 2007

Type:Error

Messages:STXV2007 ERROR Obtaining the required virtual memory area failed.

Details:

The required virtual memory area cannot be obtained. The process is canceled.
Perform the following to obtain the required virtual memory area, and try again.

-

Expand the paging file size

-

Exit unnecessary applications

Event ID: 2008

Type:Error

Messages:STXV2008 ERROR Internal inconsistency.

Details:

An internal inconsistency occurred. The process is canceled.
Refer to

"10.2 How to Obtain Error Information" (page 131)

, and prepare the required information

before contacting a Fujitsu field engineer (FE).