STXV0712 ERROR The VSSHP Management file version is invalid.

[Meaning]
The copy set management file version is invalid. The process is canceled.

[Action]
Check the VSSHP version, and try again.

STXV0713 ERROR Insufficient memory.

[Meaning]
Insufficient memory. The process is canceled.

[Action]
Exit all unused programs, and try again.
If the problem still persists, refer to

"10.2 How to Obtain Error Information" (page 131)

, and prepare the

required information before contacting a Fujitsu field engineer (FE).

STXV0714 ERROR Failed to access the target disk pool management file. iReturn =
["internal code"]

[Meaning]
Access to the target disk pool management file failed. The process is canceled.

[Action]
Reregister the target disk pool management file using the Target Disk Pool Registration/Deletion
function, and try again.
To start the Target Disk Pool Registration/Deletion function, click the [Start] button – [All Programs] –
[ETERNUS VSS Hardware Provider] – [Target Disk Pool Registration•Deletion].

STXV0801 ERROR An error occurred in the backup server.

[Meaning]
An error occurred in the backup server. The process is canceled.

[Action]
Check the events log message in the backup server and deal with the contents accordingly.

STXV0802 ERROR Communication environment with the backup server is incorrect.
("event ID")

[Meaning]
The communication environment with the backup server is incorrect. The cause is "event ID". The
process is canceled.

[Action]
Refer to

"9.1 Event Log Messages" (page 75)