Installation requirements for AC non redundant configurations

For systems not requiring AC redundancy, the power supply subsystem can be
installed with up to 4 PSUs. The PSUs can be connected to a single or multiple
AC sources.

Three power supply modules are capable of handling the maximum power
requirements for a fully configured PRIMERGY RX600 S6 server system, which
include the following:

Four processors

1024 GB of memory

Eleven PCIe add-in cards (including the SAS/SATA RAID controller card)

Eight hard disk drives and/or solid state disks

One optical drive

One tape drive

The hot swap feature allows the user to replace a failed power supply module
without affecting the system functionality.

PSU Configuration

Max. DC Loading

DC Redundancy

1+1 (2 PSUs)

830W

Yes

2+1 (3 PSUs)

1580W

Yes

3+1 (4 PSUs)

2320W

Yes

Table 3: Maximum DC Loading Requirements