100 operating manual, Css components, Rx600 s6 – FUJITSU PRIMERGY RX600 S6 User Manual
Page 100
100
Operating Manual
RX600
S6
CSS components
©
c
og
ni
ta
s.
Ges
el
ls
ch
ft f
ü
r T
e
ch
ni
k-
D
ok
um
e
nt
a
tio
n m
bH
201
1
P
fad:
C:
\P
rog
ra
m
m
e\
F
C
T
\ti
m
_a
pp
\ti
m
_l
o
ca
l\w
or
k\
P
ICH
OL
\O
B
J_
D
OK
U
-1
1
94
2-
00
1.
fm
If you want to remove an HDD/SSD module during operation, proceed as
follows:
Ê
If you want to remove an HDD/SSD module that is not defective, the drive
must be first set to "Offline" via the software (RAID controller configuration
software).
Ê
Unlock the HDD/SSD module as described in section
Ê
Pull the HDD/SSD module out a few centimeters.
Ê
Wait for at least 60 seconds.
I
This period is necessary for the RAID controller to recognize that an
HDD/SSD module has been removed and for the hard disk drive to
come to a stop.
Ê
Pull the HDD/SSD module out completely.
Ê
Install the new HDD/SSD module, as described in
V
CAUTION!
If you have removed an HDD/SSD module and do not install a new
one in its place, put the dummy module back in its place for cooling,
to comply with EMC regulations (regulations regarding
electromagnetic compatibility), and for protection against fire. Ensure
that the dummy module engages correctly in the bay.