If a memory module is installed and you pull the lever strongly
outwards, the memory module pops up. Doing so may cause a device
failure.

Please observe the safety information in

chapter "Important

information" on page 27

.

I

To guarantee that all memory modules in the relevant storage mode have
identical characteristics, you must always replace 4 memory modules
on each memory board. The only exception is memory boards running
in spare mode or in independent mode - these only require 2 memory
modules to be replaced.For more information on the individual storage
modes, see the "System Board D3141 for PRIMERGY RX600 S6
Technical Manual".

Figure 30: Removing a memory module

Ê

Press the holders on either side of the memory slot concerned outward (1).

Ê

Pull the defective memory module out of the slot (2).

/

/