Furuno NAVNET 1833 User Manual
Page 242

SP - 4
E3502S01D
6
POWER SUPPLY
6.1
Rated Voltage/Current
M1833:
12-24 VDC: 5.0-2.5 A
M1933 (24 rpm):
12-24 VDC: 6.5-3.2 A
M1933 (48rpm):
12-24 VDC: 7.8-3.9 A
M1943 (24rpm):
12-24 VDC: 7.2-3.7 A
M1943 (48rpm):
12-24 VDC: 8.0-4.0 A
6.2
Rectifier (option)
PR-62 (M1833):
100/110/220/230 VAC, 1 phase, 50/60 Hz
RU-3423 (M1933/1943): 100/110/220/230 VAC, 1 phase, 50/60 Hz
7
ENVIRONMENTAL CONDITION
7.1
Ambient Temperature
Scanner Unit: -25°C to +70°C
Display Unit: -15°C to +55°C
Remote Controller: +5°C to +45°C
7.2
Relative Humidity
93 % or less at +40°C
7.3
Waterproofing
Scanner Unit: IPX6
Display Unit: IPX5 (External monitor connected: IPX0)
Remote Controller: IPX0
7.4
Bearing Vibration
IEC 60945-3rd
8
COATING COLOR
8.1
Display Unit
N3.0
8.2
Scanner Unit
M1833:
N9.5 (upper), 2.5PB3.5/10 (lower)
M1933/1943:
N9.5
9
COMPASS SAFE DISTANCE
9.1
Display Unit
Standard: 0.85 m
Steering: 0.45 m
9.2
Scanner Unit
M1833:
Standard: 0.90 m
Steering: 0.70 m
M1933/1943:
Standard: 1.00 m
Steering: 0.75 m