FUJITSU C145-C037-01EN User Manual
Page 26
3-6
Specification
Condition
Operating
Not
Transportration
operating
or storage
(standard package)
• Printer
• Print unit
• Toner bottle
Normal
Extreme
(0.05 year)
Temperature (˚C)
10 to 32.5
0 to 40
0 to 40
-20 to 0
40 to 45
Humidity (%RH)
20 to 80
20 to 80
20 to 80
10 to 20
(no condensation)
80 to 90
Maximum wet-
29˚C
29˚C
-
-
bulb temperature
Atmospheric
-
-
0.25
pressure
(altitude: 10,300 m)
Vibration
0.2 G
0.5 G
Vertical: 1.25 G,
resistance
Horizontal: 0.75 G
Print quality excluded. 5 to 55 Hz,
Resonance frequency
13.8 minutes/cycle
excluded.
60 minutes
Vibration:
Sine wave, 5 Hz to
55 Hz, repetition of
changing frequency:
2 minutes per cycle
Direction:
Back, forth, left,
right, up, and down.
each 30 minutes.
Shock resistance
Single-side drop of 3 cm during operation
(excluding print quality)
Incline
2˚ (with flat surface)
Dust and
Ordinary office levels (stearic acid: 0.15 mg/m
3
corrosion
or less)
Drop height
One corner, three edges, and six sides
Not damaged when dropped from 45 cm height
(standard package)
Note:
This value conforms to JIS Z 0200-1987.
(Total weight: 20 to 30 kg)
MTBF
4,000 H
MTTR
0.5 H
Life
600,000 pages or five years, whichever
occurs first, at room temperature and humidity,
with preventive maintenance of the fuser unit,
etc. at the time that the printer informs of it to
the user.
No.
21
22
23
Item
Environmental conditions
Package
Reliability
Printing conditions:
• A4 landscape
• 24,000 pages/month or 1,200
pages/day (recommended)
65,000 pages/month (maximum)
• Printing mode: 4pages/job
• Powering: 8 hours/day
• Actual operating: 1 hours/day or