6.2 Error messages of the Operator panel

Hardware Alarms

[E] and a number will be displayed alternately.

*1 Turn off the scanner. Check that the SCSI cable is plugged firmly, and then turn on the scanner again.

Display

Meaning

Solution

E0

Error in the Hopper or Stacker

1.

When you encounter any alarm, turn off and on the
scanner.

2.

If doing this (step 1) does not improve the situation,

press the

and

buttons, which are labeled as

“Paper thickness” on the operator panel, for at least
2 seconds. Write down two characters displayed

between

and .

Example: In this case, “64” is displayed on the
panel.

Report the two codes from the "Display" column
and from the procedure above to the dealer where
you purchased the scanner or an authorized
FUJITSU scanner service provider.

E2

Optical system error (front)

E3

Optical system error (back)

E4

The motor fuse has blown out.

E5

The lamp fuse has blown out.

E6

Operator panel error

E7

Trouble occurred in the internal memory
(EEPROM).

E8

The SCSI fuse has blown out. (*1)

E9

Image memory error

EA

Imprinter error (*2)

Ec

Image memory error

Ed

SCSI interface or USB interface controller error

EF

Background switching mechanism error

E10

ROM error

E11

Cooling fan error

E12

Heater error

E15

Extended memory error

Confirm the following:

1.

Is the used additional memory compatible?

2.

Is the additional memory installed correctly?

3.

Is the additional memory damaged?

Note that this error will be displayed only three
times after powering the scanner on. After that, the
scanner will perform scanning in the state of no
additional memory installed.
When you encounter this E15 error, turn off and on
the scanner. If the alarm is still displayed on the
Function Number Display, contact the dealer where
you purchased the scanner or an autho-rized
FUJITSU scanner service provider.

E16

Option board error (*3)

When you encounter any alarm, turn off and on the
scanner. If the alarm is still displayed on the Func-
tion Number Display, contact the dealer where you
purchased the scanner or an authorized FUJITSU
scanner service provider.

E17

The imprinter fuse has blown out.

E18

Sensor error (*4)

E19

LSI error

E1A

Troubles occurred in the communication inside
of the scanner.

E1b

5-volt control board fuse has blown out.