beautypg.com

7 idle immediate (x'95'/x'e1') – FUJITSU MCE3130AP User Manual

Page 99

background image

C156-E142-02EN

4 - 31

Otherwise, the command ends normally. If a hardware error by which the command cannot be
executed occurs, as is the case with other commands, the command ends with Aborted Command.

Table 4.28 Error register

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

0

WRT_PT

MC

0

MCR

0

NOMED

0

WRT_PT: Set to 1 when write-protected.
MC: Set to 1 when media is exchanged. Reported only once.
MCR: Set to 1 when the Eject switch is pressed. Reported only once.
NOMED: Set to 1 when no media is inserted.

4.5.7

IDLE IMMEDIATE (X'95'/X'E1')

Table 4.29 IDLE IMMEDIATE command

Bit

7

6

5

4

3

2

1

0

CM

1

0

0

1

0

1

0

1

1

1

1

0

0

0

0

1

DH

X

X

X

DRV

X

X

X

X

CH

X

X

X

X

X

X

X

X

CL

X

X

X

X

X

X

X

X

SN

X

X

X

X

X

X

X

X

SC

X

X

X

X

X

X

X

X

FR

X

X

X

X

X

X

X

X

The ODD sets the power mode to idle mode.