4 - 12

C156-E142-02EN

4.4

Various Processes

4.4.1

Reset response

There are four types of resets.

! Power-on reset

! The ODD performs initialization such as initial diagnostics and default setting. If any

media is mounted, it also spins up media.

! Hardware reset

! The ODD is reset when the RESET- signal is asserted. The ODD initializes the interface

controller by setting default values.

! ATA reset (Software reset)

! The ODD is reset when the SRST bit of the Device Control register is set.

! The device driver should not use the SRST bit to reset the ODD (except for restore from

sleep mode).

! After ATA reset, the ODD initializes the task file as shown below.

Status = X'00'
Error = (Depending on the SRST sequence)
Sector Count = X'01'
Sector number = X'01'
Cylinder Low = X'14'
Cylinder High = X'EB'
Drive/Head = X'00'

! RDBY is set to 1 with the first command after ATA reset.

! If ATA reset is issued while the ODD is selected and a command is being executed (BSY

= 1 or DRQ = 1), the command is interrupted. Otherwise, the ODD continues command
processing.

! The contents set with the MODE SELECT and Set Features commands remain

unchanged.

! ATAPI reset

! The ODD is reset with a DEVICE RESET command. The ODD interrupts the current

command.