Read Retry Count must not be 3 or smaller. If a value of 3 or smaller is specified, the command
assumes 4 and reports Recovered Error.

Write Retry Count must not be a value other than 3. If a value other than 3 is specified, the
command assumes 3 and reports Recovered Error.

Write Retry operation is complicate and not always executed three times.

To assure media compatibility, the read-write error recovery page should be set to the default
value, except for diagnostics purposes.

The read-write error recovery page can be saved.

Table 4.55 Changeable values in the read-write recovery page

Bit

Byte

7

6

5

4

3

2

1

0

2

1

0

0

1

0

1

0

1

3

FFh

4-7

00h

8

FFh

9-11

00h

Table 4.56 Default values for the read-write recovery page

Bit

Byte

7

6

5

4

3

2

1

0

2

1

0

0

0

0

0

0

0

3

1Fh

4-7

00h

8

03h

9-11

00h