ATL Telecom AM2 User Manual
Page 3
ATL User Guide
AM2 G.SHDSL Modem
3
COMPLIANCE NOTES & SAFETY INSTRUCTIONS
Caution: - Hazardous voltages inside the equipment
Safety Instructions:
This apparatus must be installed and maintained by SERVICE PERSONNEL only
There are NO user serviceable parts inside the modem.
Caution: - Electrostatic sensitive devices inside the equipment
Electrostatic discharge (ESD) Warning:
Antistatic precautions should be observed at all times.
Power Rating Information - DC Version:
Voltage Rating
9V
Maximum Current
1000mA
Disconnect Device Statement:
For the AM2 the DC input socket serves as the disconnect device.
Safety Classification of traffic Ports
The DSL line connection has a safety status of TNV-3
10/100BaseT - 8 WAY RJ45 connections have a safety status of UNEARTHED SELV.
Safety Status Classification of non-traffic PORTS
DC Input - TNV-2
Management Port Interface - 9 WAY FEMALE D-Type connection has a safety status of EARTHED SELV.
Definitions
Exposed Environment
A TELECOMMUNICATIONS NETWORK is considered to be an exposed environment if one or more conditions
for an unexposed environment are not fulfilled.