Connecting 3-Phase AC Power to PA-4

Adept Viper s1300 Robot User’s Guide, Rev B

37

3.6

Connecting 3-Phase AC Power to PA-4

PA-4 3-Phase Power Requirements

The Adept PA-4 power chassis can be shipped from the factory configured for either
3-phase 200-240

VAC or

380-415

VAC

operation, depending on your sales order.

A voltage setting label is located on the front of the chassis below the circuit breaker. The
voltage setting is also shown on the ID label on the side of the chassis. Verify that the
setting matches your facility power before installation.

If you need to change the AC voltage setting from 200-240

VAC to

380-415

VAC, or vice

versa

, see the

Adept PA-4 Power Chassis User’s Guide

.

Table 3-1. Adept PA-4 Power Chassis 3-Phase Power Requirements

Nominal
Voltage
Range

Frequency/
Phasing

Minimum
Operating
Voltage

Maximum
Operating
Voltage

Recommended
External
Circuit Breaker
(user-supplied)

200 to 240
VAC

50-60 Hz,
3-phase

180 VAC

245 VAC

20 amps

380 to 415
VAC

50-60 Hz,
3-phase with
neutral

342 VAC

424 VAC

20 amps

Table 3-2. Typical Robot Power Consumption

a

a

Typical power data is with 220 VAC, 60 Hz, 3-phase nominal input.

Robot

Move

Average Power
(W)

Peak Power
(W)

b

b

For short durations (100 ms)

Adept Viper
s1300

No load - Adept cycle

c

c

Adept cycle: the robot tool performs continuous path, straight-line motions 25 mm up, 305 mm
over, 25 mm down, and back along the same path. COARSE is enabled and BREAKs are used
at each end location. Not achievable over all paths.

385

1871

10.0 kg - Adept cycle

c

319

1382

10.0 kg - all joints move

912

3674

WARNING:

Verify the voltage settings are correct before

turning on power. Operating the Adept PA-4 power
chassis with incorrect voltage settings can cause damage
or injury.