beautypg.com

Optional solenoid cable – Adept s1300 Viper User Manual

Page 26

background image

Chapter 2 - Robot Installation

26

Adept Viper s1300 Robot User’s Guide, Rev B

Optional Solenoid Cable

An optional 4 meter Solenoid cable is available that connects between the XDIO connector
on the SmartController and the CN20 connector on the robot. The part number is
05739-040.

Installing this cable allows you to control the three internal robot solenoids directly from
V+. See

Table 2-2

for the details on activating the individual ports on each solenoid.

In addition to controlling the internal robot solenoids, the Solenoid cable brings a portion
of the other XDIO signals out to the CN21 connector at the top of the robot. See

Table 2-3

for the details of which signals are available at CN21. See the

Adept SmartController

User’s Guide

for the electrical specifications for the signals from the XDIO connector.

Table 2-2. Viper Solenoid Control from V+

Active Output Port

V+ Signal States

a

a

The two-position, double solenoids require both V+ signal states to be
activated. Invalid states will result in indeterminate outputs.

Solenoid 1

A

0001

–0002

B

–0001

0002

Solenoid 2

A

0003

–0004

B

–0003

0004

Solenoid 3

A

0005

–0006

B

–0005

0006

Table 2-3. CN21 Signal List When Using Solenoid Cable

CN21 Pin #

Signal from XDIO on
SmartController

CN21 Pin #

Signal from XDIO on
SmartController

1

Input 1001

a

a

Inputs 1001 to 1005 are preconfigured as low-active (sinking) inputs.

6

Not connected

2

Input 1002

a

7

Output 0007

b

b

Outputs 0007 and 0008 are preconfigured as high-side (sourcing) outputs.

3

Input 1003

a

8

Output 0008

b

4

Input 1004

a

9

24V Output

c

c

Limited to a combined total of 1A of current.

5

Input 1005

a

10

Ground