Chapter 2 - Robot Installation

18

Adept Viper s1300 Robot User’s Guide, Rev B

2.2

Environmental and Facility Requirements

The Adept robot system installation must meet the operating environment requirements
shown in

Table 2-1

.

Table 2-1. Robot System Operating Environment Requirements

Item

Condition

Flatness of the mounting
surface

0.1/500 mm

Installation type

Floor-mount or Overhead-mount

Ambient temperature

During operation: 0 to 40°C
During storage and transportation: -10 to 60°C

Humidity

During operation: 90% or less (No dew condensation allowed.)
During storage and transportation: 75% or less (No dew
condensation allowed.)

Vibration

During operation: 4.9 m/s

2

(0.5G) or less

During storage and transportation: 29.4 m/s

2

(3G) or less

Safe Installation
Environment

The robot should not be installed in an environment where:

• there are flammable gases or liquids,

• there are any acidic, alkaline or other corrosive gases,

• there is sulfuric or other types of cutting or grinding oil

mist, or

• there are any large-sized inverters, high output/high

frequency transmitters, large contactors, welders, or other
sources of electrical noise.

• there are any shavings from metal processing or other

conductive material flying about,

• it may be directly exposed to water, oil, or cutting chips.

Working space, etc.

• Sufficient service space must be available for inspection and

disassembly.

• Keep wiring space (230 mm or more) behind the robot, and

fasten the wiring to the mounting face or beam so that the
weight of the cables will not be directly applied to the
connectors.

Installation conditions

Grounding resistance: 100 milliohms or less
See

Figure 2-3 on page 23

.