Installing the PA-4 Power Chassis

Adept Viper s1300 Robot User’s Guide, Rev B

35

• Use two standard Ethernet cables with a network hub or switch in place of the

Ethernet crossover cable.

NOTE: Do not use an Ethernet crossover cable with a network hub or
switch.

For more details, refer to the Adept ACE User’s Guide.

3.5

Installing the PA-4 Power Chassis

Refer to the

Adept PA-4 Power Chassis User’s Guide

for complete information on the

PA-4 chassis. This list summarizes the main steps.

1. Mount the PA-4 chassis.

NOTE: For the PA-4 in an Adept Viper system, only the panel-mounting
option is available.

2. Locate these cables, shipped in the cable/accessories box.

• IEEE 1394 cable (length 4.5M)

• XSYS cable (length 4.5M)

• Arm Power/Signal cable (length 4 M)

3. Install one end of the IEEE 1394 cable into the SmartServo port 1.1 connector on

the SmartController, and install the other end into the SmartServo port 1
connector on the sDAI module in the PA-4. See

Figure 3-1 on page 33

and

Figure

3-2 on page 36

.

4. Install the XSYS cable between the XSYS connector on the SmartController, and

the XSLV connector on the sDAI module, and tighten the latching screws.

5. Install the Arm Power/Signal cable between the CN22 connector on the robot and

the Arm Power/Signal connector on the PA-4.