IDEC WindSRV User Manual
Page 34
33
www.kepware.com
KEPServerEX5 Help
Canonical format is the following:
+
example: +1 (207) 846-5881
Note: The country code for the U.S.
is 1.
If the number is not in canonical
form, dialing preferences will not be
applied. The number will be dialed
exactly as it is entered. Users can
also enter a Phonebook tag name
instead of a phone number. In this
case, the current value of the
phonebook tag will be used.
_Status
This is the current status of the
modem assigned to a channel. For a
list of status values and meanings,
refer to
Read Only
_StringLastEvent
This contains a textual representation
of the LastEvent tag value. For a list
of event numbers and meanings,
refer to
.
Read Only
_StringStatus
This contains a textual representation
of the Status tag value. For a list of
event numbers and meanings, refer
to
Read Only
Status Values
The five lowest bits of the 32 bit status variable are currently being used.
Bit
Meaning
0
Initialized with TAPI
1
Line open
2
Connected
3
Calling
4
Answering
When read as an integer, the value of the status tag will always be one of the following:
Value
Meaning
0
Un-initialized, the channel is not usable
1
Initialized, no line open
3
Line open and the state is idle
7
Connected
11
Calling
19
Answering
Status String Values
Status Value
StringStatus Text
0
Uninitialized, channel is unusable
1
Initialized, no line open
3
Idle
7
Connected