IAI America RCM-E User Manual

Page 60

background image

52

- When soft limit is modified at the customer site, please set a value which extends 0.3mm outside of the

effective area.
Example: When setting the effective area between 0mm~80mm

Soft limit + side: 80.3
Soft limit - side: -0.3

- For RCP, RCS, E-Con, RCP2 and ERC, if the homing direction is changed, all of the inputted position

data will be cleared. As needed, please re-enter the data.

- Reversed homing direction may not be done on the Rod Type Actuator.
- Homing direction setting is reversed on the In-Line Type (SSR • SMR) Actuator (0: Correct, 1: Reversed).

Caution: Please cycle the controller power after making parameter changes.

Although pressing the emergency switch or port switch ON/OFF will rewrite the parameter,
there may be ones that will not be changed.

* Regarding parameter, please refer to the Controller Operating Manual.

Soft Limit set in controller

Effective area

Jog Increment allowable range after homing

Approx.

0.1mm

Approx.

0.3mm

Approx.

0.3mm

Approx.

0.1mm