IAI America RCM-E User Manual
Page 30
22
(7) Range:
- The “positioning operation” and “push operation” have different meanings.
Positioning operation:
It defines the distance to the target position from a position at which the position
complete signal turns ON.
The default value is 0.1 mm.
However, it defines the width of the position complete signal for the 3-point type of
PCON-C/CG, ACON-C/CG, and SCON and the proximity switch type of PCON-CY and
ACON-CY.
3-point type and proximity switch type
Standard type
Push operation:
It defines the maximum push amount from the target position in the push
operation.
Set the positioning width in such a way as to prevent positioning completion
before the actuator contacts work by considering mechanical variations of
work.
Since increasing the positioning width value
hastens the next sequence operation, it
becomes a factor for tact time reduction. Set
the optimum value by considering the
balance of the entire equipment.
Timing of position
complete signal turning ON
Positioning width
Target
position
Positioning width
Target
position
Position complete signal
ON
OFF
Position at which the position complete
signal turns ON when the actuator contacts
work and push completion is judged
Target
position
Positioning width
(maximum push amount)
Work