InFocus Laser Platform M-300 User Manual
Page 98
8-2
Troubleshooting
Raster engraving appears sharp
on both ends of the engraving
but fuzzy in the middle
•
Dirty laser system
•
Something is loose
•
System needs tuning
•
Worn X-axis belt and/or drive gear
•
Tickle setting too low
•
Faulty laser tube
•
Clean all optics, rails, bearings and belts
•
Check X-axis bearings, drive gear, idler
pulley, belt, and optics
•
Run “Tuning” feature in printer driver
version 4.17 and higher
•
Replace belt and/or drive gear, and run
“Tuning” feature
•
Adjust setting higher and recheck
•
Replace laser tube
Engraving does not appear as
deep as it normally does
•
Graphic, graphic software, graphic
software setup, color palette, monitor
display colors, or driver settings have
changed
•
Out of focus
•
Material or material density has
changed
•
Settings have changed
•
Dirty laser system
•
Laser tube cooling fan filters are dirty
•
Chiller not maintaining
temperature(water cooled versions only)
•
Ambient temperature not within
specifications
•
Laser beam out of alignment with the
optics
•
Air Assist cone misaligned (air assisted
versions only)
•
Faulty laser tube
•
Check to see what has changed. Use
“Software Setup Guide” to properly setup
the graphics software to work correctly
with the laser system. Check driver
settings.
•
Re-focus
•
Check material
•
Check power, speed, PPI, and DPI
settings
•
Clean all optics, rails, bearings and belts
•
Check and/or clean
•
Check, clean, or adjust chiller
•
Adjust ambient temperature to within
specifications
•
Check and/or adjust laser beam
alignment
•
Check and/or adjust cone so that laser
beam is in center
•
Replace laser tube
Engraving is sharp, clear and at
a good depth on one side of the
table and fuzzy and shallow on
the opposite side of the table
•
Out of focus
•
Dirty laser system
•
Material is not level or varying in
thickness
•
Table is not level
•
Laser beam out of alignment with the
optics
•
Air Assist cone misaligned (air assisted
•
Re-focus
•
Clean all optics, rails, bearings and belts
•
Check focus point of material and
different places, adjust height by
shimming material or using more
thickness-consistent material
•
Using the focus tool, focus directly on
the surface of the table in all four
corners. Table should be within +/- .020
inches from one corner to the other.
Adjust if necessary.
•
Check and/or adjust laser beam
alignment
•
Check and/or adjust cone so that laser