beautypg.com

InFocus Laser Platform M-300 User Manual

Page 98

background image

8-2

Troubleshooting


Raster engraving appears sharp
on both ends of the engraving
but fuzzy in the middle

Dirty laser system

Something is loose

System needs tuning

Worn X-axis belt and/or drive gear


Tickle setting too low

Faulty laser tube

Clean all optics, rails, bearings and belts

Check X-axis bearings, drive gear, idler
pulley, belt, and optics

Run “Tuning” feature in printer driver
version 4.17 and higher

Replace belt and/or drive gear, and run
“Tuning” feature

Adjust setting higher and recheck

Replace laser tube

Engraving does not appear as
deep as it normally does

Graphic, graphic software, graphic
software setup, color palette, monitor
display colors, or driver settings have
changed

Out of focus

Material or material density has
changed

Settings have changed

Dirty laser system

Laser tube cooling fan filters are dirty

Chiller not maintaining
temperature(water cooled versions only)

Ambient temperature not within
specifications

Laser beam out of alignment with the
optics

Air Assist cone misaligned (air assisted
versions only)

Faulty laser tube

Check to see what has changed. Use
“Software Setup Guide” to properly setup
the graphics software to work correctly
with the laser system. Check driver
settings.

Re-focus

Check material

Check power, speed, PPI, and DPI
settings

Clean all optics, rails, bearings and belts

Check and/or clean

Check, clean, or adjust chiller

Adjust ambient temperature to within
specifications

Check and/or adjust laser beam
alignment

Check and/or adjust cone so that laser
beam is in center

Replace laser tube

Engraving is sharp, clear and at
a good depth on one side of the
table and fuzzy and shallow on
the opposite side of the table

Out of focus

Dirty laser system

Material is not level or varying in
thickness


Table is not level




Laser beam out of alignment with the
optics

Air Assist cone misaligned (air assisted

Re-focus

Clean all optics, rails, bearings and belts

Check focus point of material and
different places, adjust height by
shimming material or using more
thickness-consistent material

Using the focus tool, focus directly on
the surface of the table in all four
corners. Table should be within +/- .020
inches from one corner to the other.
Adjust if necessary.

Check and/or adjust laser beam
alignment

Check and/or adjust cone so that laser