background image

When running the laser system,
the laser system will “freeze”, the
clock will keep advancing, but
the operator will have no control
over the system. The only way to
restore the system is to power
the laser off and then back on.
This is a symptom of file
corruption.

Incorrect BIOS setting in computer

Using a printer cable longer than 6 ft.

Bad printer cable

Usage of device in between computer
and laser system

Some other parallel port driver
interfering with the laser system printer
driver

Damaged port in CPU

Refer to manual on proper setting

Use only a 6 ft., IEEE1284 compliant
printer cable

Replace printer cable

Connect the laser system directly from
computer with the printer cable

Remove all other parallel port drivers
and try again

Replace laser system’s CPU