System Operation

3-5


Green Indicator Light

CONDITION

REASON

ON

The laser system is powered up, the top door is closed and the system
is ready to receive a file

The laser system has finished processing a file and has returned to the
home position

The laser system has been paused while running a file

OFF

The top or front door is open

The laser system is firing the beam in the Alignment Mode

FLASHING

The file is running


Red Indicator Light

CONDITION

REASON

ON

The laser system is initializing

The laser system is firing the beam in the Alignment Mode

OFF

The laser system has finished initializing and is ready to receive a file

The top or front door is closed

FLASHING

The top or front door is open



The Process Controls
These control the actual running of the laser system.

Runs the current file displayed in the “File Display” menu.

If a file is running, the “PAUSE” button halts the engraving or cutting process. When paused, the
motion system arm will move to its home position in the upper right corner of the engraving area.
When ready to continue operation, press the “RESUME” button and the system will begin cutting
or engraving again exactly where it left off. If you wish to run the file from the beginning after
pressing the “PAUSE” button, press the “START” button. When “Curve Enhancement” mode
is selected in the driver, the “Resume” button acts like the “Start” button and will start
your file from the beginning.

During slow raster or vector motions, the motion system might not pause immediately after the
“PAUSE” button is pressed. It can take a few seconds or several seconds to stop the system
because it needs to complete the motion commands that it is currently running. Opening the top
door also works similar to the “PAUSE” button but not exactly. The first thing the laser system
will do is turn off the laser beam immediately after the door is opened. The next thing it will do is
pause the motion system. Since opening the door and the pausing of the motion system are not
precisely synchronized if you do this, resuming the file might cause an area of missed
engraving. Opening the door to turn off the laser and to pause the motion system should only be
used for safety or emergency reasons.