POST Numeric Codes and Text Messages

This section covers those POST errors that have numeric codes associated with them. The section also
includes some text messages that may be encountered during POST.

NOTE:

The computer will beep once after a POST text message is displayed on the screen.

Table C-1

Numeric Codes and Text Messages

Control panel message

Description

Recommended action

101-Option ROM Checksum Error

System ROM or expansion board option
ROM checksum.

1.

Verify the correct ROM.

2.

Flash the ROM if needed.

3.

If an expansion board was recently
added, remove it to see if the problem
remains.

4.

Clear CMOS.

5.

If the message disappears, there may
be a problem with the expansion card.

6.

Replace the system board.

103-System Board Failure

DMA or timers.

1.

Clear CMOS.

2.

Remove expansion boards.

3.

Replace the system board.

110-Out of Memory Space for Option ROMs

Recently added PCI expansion card contains
an option ROM too large to download during
POST.

1.

If a PCI expansion card was recently
added, remove it to see if the problem
remains.

2.

In Computer Setup, set Advanced >
Device Options > NIC PXE Option
ROM Download
to DISABLE to prevent
PXE option ROM for the internal NIC
from being downloaded during POST to
free more memory for an expansion
card's option ROM. Internal PXE option
ROM is used for booting from the NIC to
a PXE server.

3.

Ensure the ACPI/USB Buffers @ Top of
Memory setting in Computer Setup is
enabled.

162-System Options Not Set

Configuration incorrect.

RTC (real-time clock) battery may need to
be replaced.

Run Computer Setup and check the
configuration in Advanced > Onboard
Devices
.

Reset the date and time under Control
Panel
. If the problem persists, replace the
RTC battery. See the Hardware Reference
Guide
for instructions on installing a new
battery, or contact an authorized dealer or
reseller for RTC battery replacement.

163-Time & Date Not Set

Invalid time or date in configuration memory.

RTC (real-time clock) battery may need to
be replaced.

Reset the date and time under Control
Panel
(Computer Setup can also be used). If
the problem persists, replace the RTC
battery. See the Hardware Reference Guide
for instructions on installing a new battery, or