HP 480-0005-00-15 User Manual
Page 118
P/N 480-0005-00-15
5-7
Chapter 5: Working with SNMP
2. Type telnet in the Open box and click on Ok.
3. Click Connect> Remote System.
4. In the Host Name window, enter the IP address of the unit from which you would like to view alarms.
5. In the port window, choose telnet (port 23 is the default port for a telnet session).
6. From the TermType drop down list, select vt100.
7. Click Connect. A telnet session will be displayed. (To exit a telnet session at any time, type exit at the
prompt.)
8. Enter the same password you set via CLI.
9. At the config - MasterChassis prompt, type set snmptrapip1
208.226.140.12. This will assign index of 1 to indicate the first network manager being assigned to that
Tenor CMS unit and assign the IP address 208.226.140.12 as the network manager. To assign the second
snmptrap ip, type set snmptrapip2
10. Repeat step 9 for each network manager (up to 3).
11. Type submit. The new IP address(es) will be submitted to the applicable Tenor CMS unit.