HP 20-Feb User Manual
Page 213
Appendix
Library Error Codes 211
Appendix C
11
0BH
Failed plunge motor
test.
■
Note the error code qualifier to help determine
appropriate testing.
12
0CH
Transport failed to
find the translate
home position.
■
Make sure that all tape cartridges are fully
seated in their slots.
13
0DH
Transport failed to
find the vertical home
position.
■
Check for a possible obstruction in the
transport pathway and remove it.
■
Verify that the vertical path is physically clear.
■
Make sure that all tape cartridges are fully
seated in their slots. (When manually loaded,
cartridges may not have been fully inserted into
slots.)
14
0EH
Transport failed to
find the plunge home
position.
■
The plunge motor can be moved. Therefore, the
motor and umbilical cable are probably not
indicated.
■
Replace the transport assembly.
15
0FH
Has wrong library
family firmware or the
controller is on the
wrong level.
Download new firmware (see
18
12H
Failed because
magazine door) is
open.
Close magazine doors.
19
13H
Vertical motor cable is
missing or faulty.
Check that the vertical cable connections are
secure.
20
14H
Transport umbilical
cable is missing or
faulty.
Check the transport cable connections or the cable
that goes from the transport to the library.
Table 46
Error Codes and Recovery Procedures
Decimal
Error
Hex
Error
Description
Recovery Method