beautypg.com

Table 18 – HP 20-Feb User Manual

Page 123

background image

Chapter 4

Understanding Error States 121

Chapter 4

To view more information about the partial availability error, you can access

the log by following this menu path:

The partial availability state is caused by one of the conditions listed in

Table

18

on page 121. The condition will be displayed on the library front panel or

the RMC Web-Based Library Administrator pages
.

Main Menu -> Information -> Library Information -> Library Status

Table 18

Partial Availability Conditions

Library Status

Cause

Solution

Drives

Drive not present

The library could not detect all the

expected drive modules.

Note:

This typically occurs because

a drive was physically removed

from the library. This may also

occur for a brief time during an

online drive repair. This condition

will persist over a power cycle.

If a drive is present in the library:

Power off the library.

Reseat the drive module.

Power on the library.

Contact your service

representative.

Drive offline

Drive taken offline because of the

following:

Taken offline from front panel,

host computer, or library

controller.

Drive(s) failed power-on test.

Drive module board failed

power-on test.

Failed serial communication to

drive.

Failed to load/unload tape.

Verify that the drive is online. If

not, put drive back online from the

front panel.

Power cycle the library.

Verify cabling and termination.

Verify that the drive is seated

properly.

Check the error log from the front

panel or RMC Web-Based Library

Administrator pages for possible

causes.

Contact your service