124 Understanding Error States
Chapter 4
Slave card failed
Library slave controller card failed
power-up test.
Note:
Slave controller cards are
required in all but the lowest level of
the library.
■
Verify that a slave card is present
in all but the lowest level of the
library.
■
Verify that the cards are properly
seated.
■
Power cycle the library.
■
Contact your service
representative.
Fibre Channel
controller failed
Fibre Channel controller failed
power-up test. (Usually due to
problems on the SCSI bus, such as
an LVDS drive or terminator on an
HVDS bus, etc.)
■
Verify that proper SCSI
terminators and/or tape drives
are attached to the Fibre Channel
controller.
■
Verify that there are no bent pins
on the controller.
■
Power cycle the library.
■
Contact your service
representative.
Front Panel
Front panel not
present
Library could not detect the front
panel display.
■
Power cycle the library.
■
Contact your service
representative.
Front panel failed
Front panel display failed power-up
test.
■
Power cycle the library
■
Contact your service
representative.
Miscellaneous
Date and time not
set
The date and time is not set on the
front panel
■
Set the date and time. (See
Door open
One or more tape doors are open.
The library robotics will not move
until the door is closed.
■
Ensure that doors are closed.
Table 18
Partial Availability Conditions
Library Status
Cause
Solution