Tools and parts, Tools and parts 17 – HP 20-Feb User Manual
Page 19
Chapter 1
Installing the 2/20, 4/40 & 6/60 Series Libraries into a Rack 17
Cha
pter 1
Installing the 2/20, 4/40 & 6/60 Series Libraries into a Rack
The instructions in this section apply to 2/20, 4/40, and 6/60 series libraries
mounted in a standard 19-inch rack with a depth between 24 and 34 inches.
Caution
Make sure that the rack and all equipment mounted in the rack
have a reliable ground connection.
Verify that the total current of the rack components does not
exceed the current rating of the power distribution unit or outlet
receptacles.
WARNING
Do not move the library without additional help or an
appropriately rated lift device. The 2/20 series library weighs
40 kg (87 lb). The 4/40 series library weighs 75 kg (165 lb).
The 6/60 series library weighs 104 kg (249 lb).
Tools and Parts
Before you begin, ensure that you have the following:
■
Phillips #2 screwdriver
■
Torx screwdriver with T20 and T25 bits
■
1/2-inch open-end wrench