beautypg.com

HP 20-Feb User Manual

Page 147

background image

Chapter 4

Troubleshooting Common Problems 145

Chapter 4

Cause: Contamination by

head staining.

(Resulting from adhesion of

chemicals that are present in

the tape media to the head

surface)

One or two passes with a cleaning tape should resolve

cleaning lights caused by normal head staining. If a cleaning

tape is unsuccessful in resolving a cleaning light after 3 or

more attempts, the cleaning tape may be contaminated, and

should NOT be used in another drive.

Cause: Temperature and

humidity

Tapes should be stored and used in the middle of the

temperature and humidity specifications range of 64-79 F, and

40-60 RH.

Cause: Non-acclimated media

A tape should be acclimated for a minimum of 24 hours before

being used, particularly if it has been stored at a substantially

different temperature or level of humidity than the tape library.

Cause: Wrong cleaning

cartridge

Only use the cleaning cartridge specifically designated for

each drive type.

Cause: Wrong tape format

Attempting to load, read, or write tapes that were written in

other formats can cause cleaning lights.

Cause: Abnormal build up of

head debris (Frequent load/

unload operations with

minimal tape reading or

writing can cause this

condition.)

Do not perform frequent load/unloads without also doing tape

operations. The front panel load/unload test should NOT be

run for more than 100 cycles since it does not perform actual

tape operations.

Cause: Bad/defective/

contaminated media

If a cleaning light is cleared using a cleaning tape, and then

immediately reappears when a particular cartridge is

reloaded, that cartridge should be suspected as being

contaminated.

If this occurs, re-clean the drive, loading a known good tape.

In rare cases, a tape cartridge can be worn out, have bad

calibration tracks, or have a bad tape directory recorded by

another drive.

Any cartridge that is suspected of being defective or

contaminated should NOT be reused in any drive.

Table 27

Troubleshooting Table

Problem