J. shut-down, I. relaxation mode, G. starting a fire - "automatic – Harman Stove Company P35I User Manual
Page 27: H. maintaining the fire

27
Pellets or Corn/Pellet Mixture Only
P35i Fireplace Insert
Save These Instructions
3-90-775R15_04/13
J. Shut-Down
During operation in ROOM TEMP/ AUTOMATIC mode,
the appliance will shut down naturally when demand is
met or exceeded. In other modes of operation, the unit
will shut-down only if or when it runs out of fuel.
To kill or stop a fire, turn the mode selector dial to
"OFF". The shut down cycle will slow or stop the
feeder to gradually cool the fire and ensure that all of
the exhaust gases are safely expelled before stopping
the combustion blower. This not only ensures removal
of all smoke and gases, it also keeps the fire from
attempting to travel into the fuel storage hopper. For this
reason; Hearth & Home Technologies recommends
installing a battery back-up in areas where frequent
power outages are experienced. (Also see page13)
NEVER ATTEMPT TO KILL A FIRE BY PULLING
THE PLUG OR OTHERWISE DISCONNECTING
THE ELECTRICITY SUPPLY.
The best way to kill a fire, especially at the end of the
heating season, is to simply allow it to run out of fuel.
I. Relaxation Mode
An added feature for those times when you'd like to
unwind watching a fire but yet do not want all the heat.
With the igniter switch in the "MANUAL" position and
the mode selector in "STOVE TEMP", your temperature
dial can be set up to a #3 and the distribution blower
will be disabled. As you turn up the temperature dial
and the fire begins to burn hotter, the distribution
blower will begin to operate.
G. Starting a Fire - "AUTOMATIC"
1. With the mode selector in the "OFF" position, and
the Feed Adjuster
NOT on "Test", plug the power
cord into a properly grounded receptacle.
2. Fill the hopper with DRY fuel.
3. Turn the FEED ADJUSTER dial to "Test". This will
run the feed motor for one minute. If you begin to
see fuel entering the burn pot, you can stop the
test cycle. Return to #4 or #5 to start out.
4. Position the Igniter switch to AUTOMATIC.
5. Turn the mode selector dial to the desired mode.
This will start the combustion blower, feeder, and
igniter operating.
If Room Temp is selected, be
sure to turn the temperature dial above the
current room temperature.
6. After the initial feed cycle is typically when you'll
begin to see sparks, smoke, or flames.
Keep Hopper Lid, Ash Pan, and Fire viewing doors
closed while in operation. Maintain all door seals
and gaskets in good condition. Replace gaskets
when necessary using parts obtained through
your Harman® dealer.
H. Maintaining the Fire
Once the Distribution Blower begins operation, your
fire is well established. Now, you can make any desired
adjustments to the temperature dial. Remember, in
STOVE TEMP, the temperature dial uses the inner
portion of the scale (#1 thru 7). In ROOM TEMP, select
the desired temperature in Fahrenheit from 50 to 90
degrees.
The flames should appear brisk and bright. If you see
deep orange and lazy flames, it is usually an indication
that the burn pot needs to be cleaned. Refer to the
Maintenance Section of this manual.
Warning! risK of fire! Keep combustible
materials, gasoline, and other flammable vapors or
liquids clear of this appliance.
• Do
NOT store flammable materials in the vicinity
of this appliance.
• DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPTHA OR
ENGINE OIL.
• DO NOT USE CHEMICALS OR FLUIDS TO
START A FIRE.
Keep all such liquids well away from the heater while it
is in use, combustible materials may ignite!