P35i Fireplace Insert

Pellets or Corn/Pellet Mixture Only

Save These Instructions

3-90-775R15_04/13

C. General Operating Information

The P35i's ESP control will maintain an output level to fit your temperature demands. There are two modes of

operation; "Stove Temp" mode, where the control will maintain a specified constant temperature, regardless of

the surrounding environment temperature conditions, Or "Room Temp" mode, where the control will adjust the

rate of burn to meet a specified room temperature setting. You also have the choice of Automatic or Manual

ignition. Regardless of the mode selected, operation is controlled by both,

exhaust temperature- being reported by the ESP (Exhaust Sensing Probe),

and the microprocessor circuit board.

We'll discuss these control devices and their functions now.

1. ESP (Exhaust Sensing Probe)

The ESP is a tiny thermistor located in the exhaust stream. The probe

changes it's thermal resistance based on minute changes in temperature,

which is monitored by the circuit board and used to determine the need for

changes in the burn rate to meet the temperature demand.

2. Circuit Board

As stated previously, the circuit board is a microprocessor, which means it has

the ability to "think" and adjust itself based on both, reported temperatures

and demand temperature. The circuit board will also flash a code sequence

on the Status light if an error is detected.

ESP Location

feed adjuster

Sets the maximum feed rate.

Test

Runs all motors at full speed for one

minute to check operation. Afterwards

the combustion blower will remain on

low burn voltage.

Temp dial

Allows you to adjust the room temperature in

Room Temp Mode using the outer scale marked

in degrees Fahrenheit. It also allows you to adjust

the stove temperature while in Stove Temp Mode

using the inner scale marked from 1 to 7.

mode selector

Allows you to choose between Room

Temp Mode, Stove Temp Mode, or

OFF. Also allows you to vary the

distribution blower speed by turning

the knob to the high or low side of

each mode.

Distribution Blower speed adjustment

range. L = low

H = high

Variable speed anywhere between L

and H; although as the stove temp.

goes up , so does the low end of the

scale.

power light

Indicates power to the control.

Indicates power to the feed motor.

Indicates power to combustion blower.

status light

Will be lit in either stove or room temp

mode when pointer is not within off

position band except after normal shut

down. Blinks to indicate errors detected.

Indicates power to distribution blower.

dealer diagnostic port

For dealer maintenance

only. Requires special DDM

monitor supplied to Harman®

Dealers exclusively.

Low Draft Adjustment Screw (see

page 26)

Indicates power to the igniter.

igniter switch

Set to appropriate Start-Up mode.