Pellets or Corn/Pellet Mixture Only

P35i Fireplace Insert

Save These Instructions

3-90-775R15_04/13

6

Mobile Home

A. Mobile Home Installation

Outside Air Kit

#1-00-774280

Must be used

for installation in a mobile home.

1. An outside air inlet must be provided for

combustion air, and must remain clear of leaves,

debris, ice, and/or snow. The outside air path must

be unrestricted while the appliance is in operation.

2. The combustion air intake system must be of

metal construction. It must permit zero-clearance

to combustible materials, and contain a rodent

screen.

3. The appliance must be secured to the mobile

home structure by bolting it to the floor. Use the

correct length lag-bolts through the same holes

that secured the appliance to the shipping pallet.

4. The appliance must be grounded to the metal

framing of the mobile home.

5. All clearances to combustibles and floor protection

requirements must be followed.

6. Follow the vent manufacturer's instructions

when installing in a mobile home. Use silicone

or equivalent to create an effective vapor barrier

where the chimney or other component penetrates

to the exterior of the mobile home.

7. Installation shall be in accordance with the

Manufactured Home and Safety Standard (HUD)

CFR 3280, Part 24

8. The appliance must never be installed in a room

designated for sleeping.

9. The space heater must be connected to a factory

built chimney conforming to CAN/ULC-S629.

Maximum 8 inch diameter. Chimney must be

removable to allow transport of mobile home.

Installation must comply with Manufactured Home and

Safety Standard (HUD), CFR 3280, Part 24.

CAUTION

Maintain structural integrity of mobile home:

• Floor, wall, ceiling and/or roof.

Do

NOT cut through:

• Floor joist, wall studs, or ceiling trusses.

• Any supporting material that would affect the

structural integrity.

CAUTION

Never draw outside combustion air from:

• Wall, floor or ceiling cavity.

• Enclosed space such as an attic or garage

There are a few holes in the bottom of the insert

mounting frame which can be used for lag bolts. Use

at least two of these holes for securing the appliance

to the fireplace floor in a mobile home installation. The

installer will need to determine and obtain the properly

sized lag bolts and masonry anchors.

Four 5/16 -18 L

eveling

bolts ma

y b

e installed

in each c

orner

Numer

ous holes allo

w

for lag b

olts (2 min.)in

mobile home installa

tion

Never install in a room intended for sleeping.

WARNING