beautypg.com

F. optional zero clearance cabinet installation, E. existing fireplace, rear vent – Harman Stove Company P35I User Manual

Page 16

background image

16

P35i Fireplace Insert

Pellets or Corn/Pellet Mixture Only

Save These Instructions

3-90-775R15_04/13

F. Optional Zero Clearance

Cabinet Installation:

If installing using the optional zero clearance cabinet,

Item

#1-00-774257,

the venting will need to exit

through the top of the cabinet. The vent can be vertical

or horizontal after leaving the cabinet. Once clear of

the cabinet, a 90 degree elbow can be installed for

rear termination as shown. Do not allow vent pipe

seams to fall within the cabinet wall. Use proper wall

thimble as supplied by the venting manufacturer.
If finishing the interior with stone or masonry, the

venting can be installed without the appliance. Install

the cabinet and secure the venting using the Flue

Rough-in Support

#1-00-774283.

The top of the chimney must also be sealed.
Otherwise, it can become a nesting area or a
water trap.

If passing through combustible
material, the proper thimble from the
vent manufacturer must be used.

M

asonr

y w

all

3" Clearance

Zero Clearance Cabinet
shown with Flue Rough-in
Support

Vent pipe seams must be
accessible.

Ver

tic

al

Ven

ting ma

y b

e used in a c

onstr

uc

ted chase

pr

oviding all clear

anc

es t

o c

ombustibles ar

e met.

Proper wall pass-thru device

as recommended by the

venting manufacturer.

E. Existing Fireplace, Rear Vent:

Notice the side edges of the surround contain slotted

openings. These openings allow room air to be drawn into the

rear of the cabinet and circulated through the heat exchange

and back into the room. These openings can not be blocked.

If finishing with stone or masonry keep

the masonry a minimum of one inch from

the sides of the surround. Mortar can be

used to give a more finished look.

NOTE: When installed in a rear vent

configuration, the maximum BTU

may be reduced due to elevated ESP

temperatures associated with the

horizontal exhaust stream.