C. venting requirements and restrictions – Harman Stove Company P35I User Manual
Page 14
14
P35i Fireplace Insert
Pellets or Corn/Pellet Mixture Only
Save These Instructions
3-90-775R15_04/13
C. Venting Requirements and
Restrictions
A combustion blower is used to extract the combustion
gases from the firebox. This causes a negative pressure
in the firebox and a positive pressure in the venting
system. The longer the vent pipe and more elbows used
in the system, the greater the flow resistance.
The recommended maximum flue lengths for the
P35i Insert are as follows:
3" or 4" Stainless Steel Flex: 30 Lineal ft. Vertical*
4" PL Vent Pipe:
4" Pl Vent Pipe: 30 Lineal ft. Vertical*
4" Pl Vent Pipe: 14 ft. Vertical w/1-90
o
and 12 lineal ft.
horizontal*
If additional 4" PL Vent fittings are required, the
overall length must be reduced by:
Vertical 90
o
or T:
2.5'
Vertical 45
o
:
1.5'
Horizontal 90
o
or T: 5.0'
Horizontal 45
o
:
2.5'
3" PL Vent Pipe:
20 Lineal ft. vertical*
8 Lineal ft. vertical w/1-90
o
& 8 lineal ft. horizontal*
If additional 3" PL Vent fittings are required, the
overall length must be reduced by:
Vertical 90
o
or T:
2.0'
Vertical 45
o
:
1.0'
Horizontal 90
o
or T: 4.0'
Horizontal 45
o
:
2.0'
*Long runs of flex or PL vent pipe installed directly
vertical from the flue stub may require more frequent
cleaning due to fly ash falling off inside and collecting
directly above the combustion blower outlet.
Any use of horizontal venting will require more frequent
cleaning. It is the responsibility of the installer to make
sure the entire flue configuration is accessible for
cleaning.
Stainless steel flex vent is only allowed for use in
masonry fireplaces and chimneys or in factory built
wood burning fireplace installations when used as a
liner for a class A metal chimney. All pellet vent pipe
must be secured together by means provided by pipe
manufacturer. The vent pipe must be secured to the
appliance flue collar with a minimum of three screws.
It is also recommended that you seal all vent pipe joints
with high temperature silicone.
Use only the specified venting components. Use
of any other components will void the product
warranty and may pose a hazard.
Do Not Install A Flue Damper In The Exhaust
Venting System Of This Appliance.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
NOTE: If burning a shelled corn and pellet mixture,
you must use approved venting components that
are specifically designed for corn burning.
Warning! risK of fire!
• Only LISTED type L or PL Pellet venting
components may be used.
• NO OTHER type of venting materials or
components may be used.
• Substitute or damaged vent components may
impair safe operation.
Warning! risK of inJury or properTy
damage!
• Improper installation, adjustment, alteration,
service, or maintenance can cause injury or
property damage.
• Read and Refer to your owner's manual.
• For assistance or additional information, consult a
qualified installer, service agency or your dealer.
IN CANADA: This fireplace insert must be installed
with a continuous chimney liner of a minimum 3"
diameter extending from the insert to the top of
the chimney. The chimney liner must conform
to the Class 3 requirements of CAN/ULC-S635,
Standard for Lining Systems for Existing Masonry
or Factory Built Chimneys and Vents, or CAN/
ULC-S640, Standard for Lining Systems for New
Masonry Chimneys.