sv6 diagnostics
Use the diagnostic tool for troubleshooting. The executable is
/usr/local/bin/sv6diag
. More usage details can be found by view-
ing the man page for sv6diag, or running
sv6diag -h
. Diagnostic
results are generated as a table showing the pass/fail status for each
component in the system.
sv6diag runs the following sequence of tests:
Back - Verifies name resolution on slaves
Comp - Tests RS232 connectivity to the compositor(s)
Digi - Verifies connectivity to slaves through the Digi-Etherlite terminal
server
Forw - Verifies name resolution on master
Giga - Tests connectivity on 1000 baseT network
Ping - Verifies connectivity to terminal server
Rsh - Verifies Remote Shell Capability
Tnet - Tests connectivity on 10/100baseT network
Usage: To run the test suite, type:
sv6diag [-abcdglnprt]
Description:
Runs diagnostic tests on sv6 systems.
All tests run by default without logging.
Options:
a - Run all tests
b - Verify name resolution on slaves
c - Test connectivity to the compositor(s)
d - Verify connectivity to slaves through the terminal server
g - Test connectivity on 1000baseT network
l - Turn logging on
n - Verify name resolution on master
p - Verify connectivity to terminal server
r - Verify Remote Shell Capability
t - Test connectivity on 10/100baseT network
Executing sv6diag with no arguments runs all of the tests.