beautypg.com

Step 4: verification – HP sv6 User Manual

Page 54

background image

installation and user information

updating software

Chapter 2

54

(

Actions)

(Add Target Group)

name:

/var/opt/ignite/sps/sv6files/sv6_targets

[OK]

(Actions)

(Show Software For Selection)

Source Host Name:

svm

Source Depot Path: /

var/opt/sps/depots

[OK]

12. In the software selection window:

Left click to select PHNE_25612
Right click on PHNE_25612
(

Mark For Install)

(Actions)

(Install)

Assign an optional job title for monitoring and reference pur-
poses.

Example:

march gb patch

[OK] [OK]

Watch the Job Browser and Job Results window for confirmation,
warning, or error messages, which may need your response.

[Done]

step 4: verification

13. Check logs for errors.

Highlight the system with errors or warnings, then click

[Show Log]

.

Copies of SD logs can be found at /var/adm/sw/*.log

14. If a pop-up window requests a mandatory reboot, click

[Done]

. By

default, auto-reboot is disabled for the master node only, so the
slaves will automatically reboot.

Reboot the master system:

/sbin/reboot –q

15. Verify that the new software shows up in the software list.

swlist |grep PHNE_25612

The name and description should show up as output. Example:

PHNE_25612 1.0 1000Base-SX/T B.11.00.[02-11] cumul. patch