Command transmission method
Transmit in the following command format
Transmitted data
Header
Data part
Last
terminal
symbol
Hash value
(see
“Connection
method”)
‘0’
0x30
‘0’
0x30
Control
command
(ASCII
character
string)
(CR)
0x0d
32 bytes
1 byte
1 byte Undefined 1 byte
Received data
Header
Data part
Last
terminal
symbol
‘0’
0x30
‘0’
0x30
Control
command
(ASCII
character
string)
(CR)
0x0d
1 byte
1 byte
Undefined
1 byte
Error response
Error message
Last
terminal
symbol
“ERR1”
: Undefined control
command
(CR)
0x0d
“ERR2”
: Out of parameter range
“ERR3”
: Busy status or
reception invalid period
“ERR4”
: Timeout or reception
invalid period
“ERR5”
: Wrong data length
“ERRA”
: Mismatching of
password
4 bytes
1 byte
■
When the WEB control administrator
privileges password has not been set (Non-
protect mode)
Connection method
1
Obtain the display’s IP address and the port number
(Default is 1024), and request connection to the
display.
The IP address and the port number can be obtained
from the following menus.
•
IP address:
[Setup
] → [
Network settings
] → [
LAN setup] or
[Network status]
•
Port number:
[Setup
] → [
Network settings
] → [
LAN setup]
●
For more detail of the settings, see page 78.
2
The display responds.
Response data
Data part
Space
Mode
Last
terminal
symbol
[NTCONTROL]
(ASCII
character
string)
[ ]
0x20
[0]
0x30
(CR)
0x0d
9 bytes
1 byte
1 byte
1 byte
Mode: 0 = Non-protect mode
Command transmission method
Transmit in the following command format
Transmitted data
Header
Data part
Last
terminal
symbol
‘0’
0x30
‘0’
0x30
Control
command
(ASCII
character
string)
(CR)
0x0d
1 byte
1 byte
Undefined
1 byte
Received data
Header
Data part
Last
terminal
symbol
‘0’
0x30
‘0’
0x30
Control
command
(ASCII
character
string)
(CR)
0x0d
1 byte
1 byte
Undefined
1 byte