Panasonic TH-65SQ1WA 65" Class 4K HDR Commercial Monitor User Manual
Page 79
79
English
[User name]
Enter the user name for authentication with one-byte
alphanumeric characters (excluding space). (Up to 64
characters)
This can be set only when [EAP] is set to items other
than [None] or [EAP-TLS].
[Password]
Enter the password for authentication with one-byte
alphanumeric characters. (Up to 64 characters)
This can be set only when [EAP] is set to items other
than [None] or [EAP-TLS].
Note
●
For 98 and 86 inch models, [EAP], [User name]
and [Password] are displayed only when the main
software version is 4.0000 or later.
●
When EAP is used, this unit needs to be configured
according to the settings of the RADIUS server.
For the settings of the RADIUS server, consult with
the network administrator.
●
When [EAP] is set to [EAP-TLS], set [Date and time]
(see page 76) and register the certificate on the WEB
browser control. (see page 103)
[MAC address]
Displays the MAC address of this unit.
■
[Network status]
Checks the current Network settings status.
192. 168. 0. 1
255. 255. 255. 0
192. 168. 0. 8
12:34:56:78:9A:BC
Network status
DHCP
IP address
Subnet mask
Gateway
EAP
Off
None
MAC address
Note
●
For 98 and 86 inch models, [EAP] is set only when
the main software version is 4.0000 or later.
■
[DIGITAL LINK mode]
Switches communication method of DIGITAL LINK
terminal.
[Auto]:
Communication method is selected automatically.
HDMI, LAN, serial communication are possible.
Ethernet connection is possible.
[DIGITAL LINK]:
HDMI, LAN, serial communication are possible via a
twisted pair cable transmitter.
[Ethernet]:
LAN communication is possible via the LAN terminal
of the display.
[Long reach]:
Communication method is fixed to Long reach.
Modes allowing communication
:
Valid
― :
Invalid
Settings
Communication validity
Picture
transmission Ethernet RS-
232C
100 m 150 m
Auto
For
DIGITAL
LINK
―
For Long
reach
―
For
Ethernet
―
―
―
DIGITAL LINK
―
Long reach
―
Ethernet
―
―
―
Note
●
When connected with the [Long reach]
communication method, the maximum
transmission distance is 150 m. In this case, this
unit can receive the signals of up to 1080/60p
(148.5 MHz).
●
If the communication method of the twisted
pair cable transmitter is set to [Long reach], set
[DIGITAL LINK mode] to [Auto]. Then, connection
is enabled with the [Long reach] communication
method.
When connecting with the separately sold DIGITAL
LINK Switcher (ET-YFB200G) with the [Long
reach] communication method, set [DIGITAL LINK
mode] to [Long reach].
●
Even if [DIGITAL LINK mode] is set to [Long
reach], when the twisted pair cable transmitter
does not support the communication method of
[Long reach], it will not be connected properly.