Parameter
Value
Explanation
Def
Recording time: 25 sec (max.)
Long
Recording time: 40 sec (max.)
Reverse Type
This selects the point (time) at which reverse playback begins when you press the [REVERSE] button during
sample playback.
404
Starts reverse playback at the sample’s end point. This works the same as the SP-404SX.
303
Starts reverse playback immediately from the playback position of the current sample.
This works the same as the SP-303.
USB IN
This selects where the audio signal input from the USB port is sent.
LINE IN
Mixes the USB audio signal with the audio signal from the LINE IN jacks.
MIX OUT
Mixes the USB audio signal with the MIXER output, without going through the INPUT
FX or BUS FX.
DJ mode TS
type
This lets you change how the audio is processed when changing the playback speed of a sample in DJ
mode.
VINYL
Changes the playback speed and pitch at the same time, like an analog record.
BACKING
Independently controls the playback speed and pitch.
Processes the sound as appropriate for musical instruments whose sounds have a
noticeable decay.
ENSEMBLE
Independently controls the playback speed and pitch.
Processes the sound as appropriate for musical instruments that have a sustaining
sound.
Bend Sens
(DJ)
10–200
Sets how quickly the pitch of a sample changes when you press the [BEND-] and
[BEND+] pads.
FileSystem
Selects the character code for filenames that can be recognized by this unit when you import a sample.
●
The unit must be restarted once you’ve changed the settings and pressed the [EXIT] button to exit the
SYSTEM screen.
Multi-Byte
Letters, numbers, symbols, double-byte characters (kanji, hiragana, katakana)
●
This lets the unit recognize and import files with filename that use double-byte
and similar characters. Note that this unit doesn’t correctly display double-byte
characters, and these characters appear garbled.
Latin1
Letters, numbers, symbols
●
With this setting, files with double-byte characters in their filenames can’t be
recognized by this unit.
CLICK
Parameter
Value
Explanation
Output Assign
OFF, ON
When this is set to ON, the metronome sound is output from the LINE OUT jacks and from
the USB port.
Click Level
1–5
Sets the volume of the metronome.
Metronome:REC OFF, ON
When this is ON, the metronome sound is output while you are sampling or resampling.
Metronome:PTN OFF, ON
When this is ON, the metronome sound is output when a pattern is being recorded.
Count-In:REC
This selects how sampling or resampling starts.
OFF
Sampling or resampling starts at the same time that you press the [REC] button.
1 MEAS, 2
MEAS
When you press the [REC] button, a count-in begins one or two measures before where
sampling or resampling begins.
WAIT
Sampling or resampling starts when you press a pad to play back a sample, or when
audio is detected from an external device.
Count-In:PTN
This selects how pattern recording begins.
OFF
Pattern recording starts at the same time that you press the [REC] button.
1 MEAS, 2
MEAS
When you press the [REC] button, a count-in of one or two measures begins before
pattern recording starts.
WAIT
Pattern recording starts when you press a pad to play back a sample, or when audio is
detected from an external device.
MIDI