11 i/o, 12 power management, 13 system management – Endura RADISYS KP915GV User Manual
Page 30: 14 security

KP915GV Product Manual
30
2.11 I/O
•
Four USB 2.0 ports on I/O panel via two dual stacked USB over RJ45 connectors
•
Four USB 2.0 ports on internal locking headers
•
Available with IEEE 1394b controller with support for 1394a
•
Single port via a header connector
•
Based on Texas Instruments TSB82AA2 controller and TSB81BA3 transceiver
2.12 Power
Management
•
Supports ACPI 2.0 with power states S0, S3, S4 (not S4BIOS), S5 and C0, C1, C2, C3
•
Supports PCI PME and PCI Express power management event signaling
Table 3. ACPI Power States
G0/S0/C0 Full
on
G0/S0/C1
Processor is halted
G0/S0/C2
Processor stops internal clocks
G0/S0/C3
Processor clocks are disabled and processor in sleep state
G1/S3
System context is saved to RAM and power removed from all circuits
except that required to maintain system RAM and resume
G1/S4
System context is saved to disk and power removed from all circuits
except that required to resume
G2/S5
Soft off, only resume logic and RTC remain powered
2.13 System
management
•
System monitoring of voltage, temperature, fans
•
Temperature monitoring of processor die, board and remote sensor
•
Direct monitoring of lithium cell voltage
•
Automatic fan control for 3 fans - CPU, System 1, System 2
•
Fan configuration held in BIOS customization block
•
Fans can be assigned to any of three thermal zones for automatic control - each zone
•
monitored by one of the three thermal sensors
•
450mA drive capability for each system fan, 2.2A for the CPU fan
•
Anti-tamper security (trigger for chassis intrusion detect)
•
Programmable watchdog timer with range of 1 second to 1 hour
•
Access to SMBus via 4-pin 2mm header
2.14 Security
•
Header for Trusted Platform Module (TPM)
•
TCG 1.1 compliant