ProSoft Technology 5204-DFNT-PDPMV1 User Manual
Page 37
DFNT ♦ ProLinx Gateway
Configuring the Gateway
EtherNet/IP Explicit Messaging Client/Server
Protocol Manual
ProSoft Technology, Inc.
Page 37 of 124
July 24, 2013
SLC-500 Command Set Functions
Function
Code
Command Function Definition
PLC5
SLC500 &
MicroLogix
Power-
monitor II
ControlLogix
501
0x0F
0xA1
Protected Typed
Logical Read With
Two Address Fields
X
X
502
0x0F
0XA2
Protected Typed
Logical Read With
Three Address Fields
X
X
X
509
0x0F
0XA9
Protected Typed
Logical Write With
Two Address Fields
X
X
510
0x0F
0XAA
Protected Typed
Logical Write With
Three Address Fields
X
X
X
511
0x0F
0XAB
Protected Typed
Logical Write With
Mask (Three Address
Fields)
X
X
Each command list record has the same general format. The first part of the
record contains the information relating to the communication module and the
second part contains information required to interface to the DF1 or EtherNet/IP
slave device.
- 5205-DFNT-PDPS 5202-DFNT-MCM4 5201-DFNT-MCM 5201-DFNT-104S 5207-DFNT-HART 5228-DFNT-HART 5208-DFNT-HART 5201-DFNT-EGD 5202-DFNT-GRCM4 5201-DFNT-GRCM 5201-DFNT-DNPS 5201-DFNT-DNPSNET 5201-DFNT-DNPM 5201-DFNT-DH485 5202-DFNT-DFCM4 5201-DFNT-DFCM 5201-DFNT-BACNET 5201-DFNT-ASCII 5210-DFNT-RIO 5303-MBP-DFNT 5201-MNET-DFNT 5201-DFNT-104C