Reference
DFNT ♦ ProLinx Gateway
Protocol Manual
EtherNet/IP Explicit Messaging Client/Server
Page 112 of 124
ProSoft Technology, Inc.
July 24, 2013
The M
ULTI
H
OP
option must be set to Y
ES
.
The M
ULTI
H
OP
tab portion of the dialog
box must be completed as shown in the following window:
Set the IP address value to the module’s Ethernet IP address. You must press
the "Insert" key to add the second line for ControlLogix Backplane and set the
slot number to zero.
5.10.2 PLC5 Read Commands
Read commands transfer data to the PLC5 processor from the DFNT module. An
example rung used to execute a read command is shown in the following
diagram:
In order to complete the configuration of the MSG instruction, select the S
ETUP
S
CREEN
area of the MSG object. This displays the following dialog box.
Select the C
OMMUNICATION
C
OMMAND
to execute from the following list of
supported commands.
PLC5 Type Read
PLC2 Unprotected Read
PLC5 Typed Read to PLC
PLC Typed Logical Read
- 5205-DFNT-PDPS 5202-DFNT-MCM4 5201-DFNT-MCM 5201-DFNT-104S 5207-DFNT-HART 5228-DFNT-HART 5208-DFNT-HART 5201-DFNT-EGD 5202-DFNT-GRCM4 5201-DFNT-GRCM 5201-DFNT-DNPS 5201-DFNT-DNPSNET 5201-DFNT-DNPM 5201-DFNT-DH485 5202-DFNT-DFCM4 5201-DFNT-DFCM 5201-DFNT-BACNET 5201-DFNT-ASCII 5210-DFNT-RIO 5303-MBP-DFNT 5201-MNET-DFNT 5201-DFNT-104C