DFNT ♦ ProLinx Gateway
Reference
EtherNet/IP Explicit Messaging Client/Server
Protocol Manual
ProSoft Technology, Inc.
Page 109 of 124
July 24, 2013
The M
ESSAGE
C
ONFIGURATION
dialog box must be completed to define the data
set to transfer to the processor from the module. An example of the dialog box
follows:
Complete the dialog box for the data area to be transferred. CIP Data Table
messages require a tag database element for both the source and destination.
The D
ESTINATION
T
AG
is a tag defined in the ControlLogix Tag database. The
S
OURCE
E
LEMENT
is the tag element in the DFNT module. The module simulates
a tag database as an array of elements defined by the maximum register size for
the module (user configuration parameter "Maximum Register" in the [Module]
section) with the tag name
INT
_
DATA
.
In the example above, the first element in
the database is the starting location for the read operation of ten elements.
Additionally, the C
OMMUNICATION
information must also be configured. An
example of the dialog box follows:
- 5205-DFNT-PDPS 5202-DFNT-MCM4 5201-DFNT-MCM 5201-DFNT-104S 5207-DFNT-HART 5228-DFNT-HART 5208-DFNT-HART 5201-DFNT-EGD 5202-DFNT-GRCM4 5201-DFNT-GRCM 5201-DFNT-DNPS 5201-DFNT-DNPSNET 5201-DFNT-DNPM 5201-DFNT-DH485 5202-DFNT-DFCM4 5201-DFNT-DFCM 5201-DFNT-BACNET 5201-DFNT-ASCII 5210-DFNT-RIO 5303-MBP-DFNT 5201-MNET-DFNT 5201-DFNT-104C