Diagnostics and Troubleshooting

MVI56-PDPS ♦ ControlLogix Platform

Profibus DP Slave Communication Module

ProSoft Technology, Inc.

Page 49 of 88

April 22, 2008

Cfg Len is the configuration length for the slave with S as the pointer.

RCfg len is that received from the master with S as the pointer.

Ident is the PROFIBUS identification number for the module.

FDL SAP last PTR is the end of all the PDPS data in the SPC3 chip. This value
must be less than 0xFF or there is a memory overflow problem!

Comm Failure mode is that from the configuration file as is the swapping of input
and output data.

Viewing PROFIBUS Status

Enable State
Indicates the initialized state of the MVI56-PDPS module.
ƒ

0 = Module is not initialized

ƒ

1 = Module is initialized

Module State

Indicates the current state of the MVI56-PDPS module.
ƒ

0 = Normal Operation

ƒ

1 = Shutdown

ƒ

2 = File Transfer

ƒ

3 = SPC3 ASIC problem

ƒ

4 = Not in data exchange

Status Register [0]
SPC3 ASIC slave status information provided to the master.

Offline/Passive-Idle
Offline-/Passive-Idle state

Bit 0

0 = SPC3 is in offline
1 = SPC3 in passive idle

FDL_IND_ST (Fieldbus Data link Layer)
FDL indication is temporarily buffered.

Bit 1

0 = No FDL indication is temporarily buffered.
1 = FDL indication is temporarily buffered.