4.16.6 PoE Status

This page allows the user to inspect the total power consumption, total power reserved and current status for all PoE ports. The

screen in

Figure 4-16-5

appears.

Figure 4-16-5:

PoE Status Screenshot

The page includes the following fields:

Object

Description

Shows the total watts usage of Managed PoE Switch.

Current Power

Consumption

Total Power Reserved

Shows how much the total power be reserved for all PDs.

Displays the current operating temperature of first PoE chip unit.

Temperature

This is the logical port number for this row.

Local Port

Displays the class of the PD attached to the port, as established by the classification

process. Class 0 is the default for PDs. The PD is powered based on PoE Class

level if system working on Classification mode. A PD will return Class to 0 to 4 in

accordance with the maximum power draw as specified by

Table 4-16-1

.

PD Class

The Power Used shows how much power the PD currently is using.

Power Used [W]

The Power Used shows how much current the PD currently is using.

Current Used [mA]

Priority

The Priority shows the port's priority configured by the user.