beautypg.com

2 status – PLANET MGSD-10080F User Manual

Page 328

background image

User’s Manual of MGSD-10080F

328

604800 seconds (7 days). A value of zero will keep a port disabled (until next

device restart).

Port Configuration:

Object

Description

Port

The switch port number of the port.

Enable

Controls whether loop protection is enabled on this switch port.

Action

Configures the action performed when a loop is detected on a port. Valid values

are Shutdown Port, Shutdown Port and Log or Log Only.

Tx Mode

Controls whether the port is actively generating loop protection PDU's, or

whether it is just passively looking for looped PDU's.

Buttons

: Click to save changes.

:

Click to undo any changes made locally and revert to previously saved values.

4.16.2 Status

This page displays the loop protection port status the ports from the Managed Switch.

Figure 4-16-2: Loop Protection Status Page Screenshot

The page includes the following fields:

Object

Description

Port

The switch port number of the logical port.

Action

The currently configured port action.

Transmit

The currently configured port transmit mode.

Loops

The number of loops detected on this port.