Installation abort – Avago Technologies AcceleRAID 150 User Manual
Page 60
Installation Abort
C-2
AcceleRAID 150 Installation Guide
During the initialization, if the firmware fails to respond to the BIOS inquiry
within two minutes, the following message displays:
DAC960P
n
not responding--no drives installed.
The BIOS then inquires the firmware for its version number and other
information, and prints out the following message:
DAC960P
n
firmware version x.xx
One or more of the following messages will be displayed if the firmware
reports the following conditions:
Warning: X system drives are offline
Warning: X system drives are critical
Warning: The following SCSI devices are dead--chn
x, tgt y...
No system drives found: None installed
X system drives installed
The BIOS repeats the same process for additional RAID controllers present
in the system. Then it proceeds to boot, if possible, from the first system
drive on the first controller.
Installation Abort
With Firmware 4.x, the installation aborted message is displayed when the
BIOS finds that the configuration of the disk drives, as stored in the
NVRAM and configuration on disk, is different from what it senses at boot
time. When this happens, (and a brand new installation is not being
attempted) the cause is often a faulty cable or drive, or a loose connection.
Check all of the connectors, cables, and drives and try to boot. If the error
persists, it most likely indicates a genuine failure and needs to be corrected.
To correct it, run the RAID EzAssist (previously BIOS) Configuration
Utility. For more information, refer to the RAID EzAssist Configuration
Utility User Reference Guide or RAID EzAssist Configuration Utility Quick
Configuration Guide available on CD-ROM.