Controller Installation (SISL)
2-24
AcceleRAID 150 Installation Guide
7. Connect the SCSI cables from the disk drives to the drive channels, as
required, according to the example shown in Figure 2-21.
(The controller is already connected to the system board.) If necessary,
refer to Table A-1 on page A-1 for SCSI formats and bus lengths.
☛
Note
In order to ensure an error free environment, the
proper cable type designed for a certain SCSI
speed must be used.
☛
Note
Wide and narrow SCSI disk drives must not be
installed together (mixed) on any one channel, or the
AcceleRAID controller may not work properly. It is
ok to mix wide and narrow connections for other
devices, but do not mix SCSI disk drives.
Figure 2-21. AcceleRAID 150 Typical SISL Installation showing channels
☛
Note
It is recommended that non-RAID SCSI devices be
connected to a separate SCSI channel, either on the
system board or furnished by a SCSI host bus adapter
such as a Mylex FlashPoint controller.
See Appendix A for information on LVD mode and
single-ended mode.
T
Plug Controller into
the Specially Wired
SISL PCI Slot
Wide SCSI
Connector
on System
Board
(Ch 1)
System Board
Narrow
SCSI
Connector
on System
Board (Ch 2)
Channel 0
T