Standard Installation Checklist

2-4

AcceleRAID 150 Installation Guide

Standard Installation Checklist

GET READY

Note

It is recommended that you wear a grounded wrist
strap when working with hardware installation
procedures.

1. ____ Decide which available standard PCI slot will be used.

2. ____ Remove the plate from the I/O access port to the PCI slot.

3. ____ Remove the AcceleRAID 150 controller from the anti-static bag.

4. ____ Check Jumper 10 (JP10). If it is installed on the jumper pins,

remove it according to Figure 2-6.

GET SET

5. ____ Plug the AcceleRAID 150 controller into a standard PCI slot.

6. ____ Tighten the AcceleRAID 150 controller into the mounting

bracket.

7. ____ Connect the SCSI cable(s) drives and/or devices to the controller.

8. ____ Check termination – Only internal or external devices.

9. ____ Check termination – Both internal and external devices.

10. ____ Remove or set termination jumpers to the disabled position on

the disk drive.

11. ____ Set SCSI ID on the disk drive.

12. ____ Enable termination power on disk drives.

13. ____ Safety check the installation.

Note

Review Figure 2-1 and Table 2-1 to get familiar with
the layout of the AcceleRAID 150 controller and the
Connectors, Jumpers, and LED descriptions.

GO

14. ____ Go to Chapter 3, Controller Start-up.