Enterasys Networks Security Router X-PeditionTM User Manual
Page 428

System Alarms and Events
A-6 Alarms/Events, System Limits, and Standard ASCII Table
ETH1_
DRIV
The ISR could not be connected
This is internal configuration alarm occurs because the interrupt
service routine (ISR) cannot be connected to the FastEthernet 2
interface/driver, rendering FastEthernet port 2 unavailable.
ETH1_
DRIV
Init string parse failure
This internal configuration alarm is due to the driver being unable to
parse its initialization string, rendering FastEthernet port 2
unavailable.
ETH1_
DRIV
Unrecoverable error
The FastEthernet 2 chip on the motherboard has severe problems -
a catastrophic failure. The most likely cause is a hardware failure.
When this alarm occurs, FastEthernet port 2 is unavailable.
ETH1_
DRIV
OS initialization failure
This internal configuration alarm occurs because the operating
system initialization of the driver/interface cannot be completed,
rendering FastEthernet port 2 unavailable.
ETH1_
DRIV
Device not found
Most likely this occurs due to a hardware failure - the FastEthernet 2
chip cannot be found on the PCI bus (of the motherboard). When this
occurs, FastEthernet port 2 is unavailable.
ETH0_
DRIV
The device is stuck in reset
The FastEthernet 1 chip on the motherboard has severe problems -
it cannot come out of reset and the FastEthernet 1 driver/interface
cannot be started. The most likely cause is a hardware failure. When
this alarm occurs, FastEthernet port 1 is not available.
ETH0_
DRIV
The ISR could not be connected
This internal configuration alarm occurs because the interrupt
service routine (ISR) cannot be connected to the FastEthernet 1
interface/driver, rendering FastEthernet port 1 unavailable.
ETH0_
DRIV
Init string parse failure
This internal configuration alarm occurs because the driver could not
parse its initialization string, rendering FastEthernet port 1
unavailable.
ETH0_
DRIV
OS initialization failure
This internal configuration alarm occurs because the operating
system initialization of the driver/interface cannot be completed,
rendering the FastEthernet 1 interface unavailable.
CLI
Failed to create session for web access
Failure to start session for the Web.
CLI
Failed to create session for console access Failure to start session for the Web.
CLI
Failed to create session for telnet access
Failure to start session for console.
CLI
Failed to create session for telnet access
Failure to start session for Telnet.
CLI
Failed to enable Telnet server
Cannot start Telnet server because socket open failed.
CLI
Failed to enable Telnet server
Cannot start Telnet server because socket bind failed.
CLI
Failed to enable Telnet server
Cannot start Telnet server because socket listen failed.
CLI
Failed to enable Telnet server
Failure to enable the Telnet server.
CLI
CLI Config mode released by user
A user exits Configuration mode.
CLI
CLI Config mode released by user
An unknown user exits Configuration mode.
CLI
CLI config mode released by startup-config Configuration mode is released when the startup-config script
finishes execution.
Table A-6 High Severity Alarms/Events (continued)
Module
Message
Description